Cellulose Insulation Manufacturers Association Logo
Member Login Contact Us
NATURALLY BETTER INSULATION
RESOURCES
CONTRACTOR REFERRALS
CIMA CIMA Video ChannelChannel
CIMA Video - Greenest of the Green The Greenest of the Green
CIMA Video - Cellulose Insulation Installation Demonstration No Building Insulation Fire Test
CIMA Video - Cellulose Insulation Installation Demonstration Sprayed Cellulose Insulation Building Fire Test
CIMA Video - Cellulose Insulation Installation Demonstration Fiberglass Batt Insulaton Building Fire Test
CIMA Video - Cellulose Insulation Installation Demonstration Fiberglass Blown-in Insulation Test
CIMA Video - Cellulose Insulation Installation Demonstration Installation Demonstration
CIMA Video - Cellulose Insulation in the Home Cellulose Insulation in the Home
CIMA Video - The Green Build Expo CIMA at the Green Build Expo
What R-Value
R-Value =
temp diff X area X time

heat loss
Really Means

Calculate Your

Insulation Savings

Cellulose Insulation Manufacturers Association Blog and NewsLatest News Goto the Blog -->

Table of Environmental Facts For Most Popular Insulation Types

The table below is a summary of information taken from the January 1, 2005 Environmental Building News and highlights some of the key environmental impacts of selected insulation types.

Please note that there is no “generic” R-value for the different type of insulations. Each manufacturer has different R-values so check the label on the packaging for specific recommendations. We have included a range to provide the relative of comparison of the various insulation R-values.

Type
Installation Methods
R-value per inch (RSI/m)
Raw Materials
Pollution From Manufacture
Indoor Air Quality Impacts
Comments
Cellulose Loose-fill, wall-spray (damp), dense pack, stabilized 3.6-4.0
(21-26)
Old Newspapers, telephone directories, borates, ammonium sulfate Negligible Fibers and chemicals can be irritants High recycled content and very low embodied energy
Fiberglass Batts, Loose-fill, semi-rigid board 3.0-4.0
(15-28)
Silica sand, limestone, boron, recycled glass, PF resin or acrylic resin Formaldehyde emissions and high energy use during manufacture Fibers can be irritants High embodied energy
Mineral Wool Loose-fill, batts, semi-rigid or rigid board 2.8-3.7
(19-26)
Iron ore blast furnace slag, natural rock, PF binder Formaldehyde emissions and high energy use during manufacture Fibers can be irritants High embodied energy; Rigid board can be an excellent foundation drainage and insulator
Cotton Batts 3.0-3.7
(21-26)
Cotton and polyester mill scraps (especially denim) Negligible Considered safe Two producers, so transportation pollution is higher than other insulation
Closed-cell spray polyurethane foams Spray-in cavity-fill or spray-on roofing 5.8-6.8
(40-47)
Fossil fuels; HFC-24.5fa blowing agent; non-brominated flame retardant High energy use during manufacture; global warming potential from HFC blowing agent Quite toxic during installation (respirators or supplied air required); allow several days of airing out prior to occupancy Very High embodied Energy
Open-celled, low-density polyurethane foam (Soy) Spray-in cavity-fill 3.6-3.8
(25-27)
Fossil fuels and soybeans; water as blowing agent; non-brominated flame retardant High energy use during manufacture Quite toxic during installation (respirators or supplied air required); allow several days of airing out prior to occupancy Very High embodied energy

Contact Us for assistance or with questions about cellulose insulation.

Home Industry Professionals
Architects
Builders
Insulation Contractors
Insulation Performance & Value
Performance Features Table
Insulation Myths
Insulation Costs
Sound Control
Fire Control
Air/Vapor Barrier
Low Carbon Footprint Homes
Insulation Tech Data/Research
Marketing Materials
Equipment Suppliers
Links
FAQ
Homeowners
Insulation Basics
Why Insulate
Where to put Insulation
Types of Insulation
What R-value Means
Incentives & Tax Credits
Insulation Performance & Value
Performance Features Table
Insulation Myths
Insulation Savings Calculator
Air/Vapor Barrier
Sound Control
Fire Control
Installing Insulation
DIY Installation
Dry Blow-in Insulation
Sprayed Insulation
Retrofit Installations
Selecting A Contractor
Hiring Insulation Contractors
Insulation Contractor Referrals
Insulation Tech Data/Research
Links
FAQ
Environmental
Eco-Friendly Cellulose Insulation
Cellulose Insulation Environmental Facts
Environmental Facts Table
Recycle Paper Into Insulation
Low Embodied Energy
Regionally Produced Products
No Product Waste
Low Carbon Footprint Homes
Greenest of the Green
Greenest of Green Campaign
Cellulose Insulation Green Facts
Greenest Insulation Blog
About CIMA
Producer Members
Associate Members
Board of Directors
Standing Committees
Staff Members
Find Insulation Contractors
Equipment Suppliers
Contact Us
News
Blog
News Releases
133 S. Keowee St., Dayton, OH 45402 • Ph: 937-222-2462 • Toll Free: 888-881-2462 • Fax: 937-506-8060
© 2013-2017 Cellulose Insulation Manufacturers Association • info@cellulose.orgPrivacy Policy